Inspection of fastener surface treatment

Mar 18, 2020

Leave a message

1.Gage method

       The amount used has a micrometre, vernier calliper, plug gauge, etc.

       2.Magnetic method

       The magnetic method for measuring the thickness of a zinc coating layer is a non-destructive measurement of a non-magnetic coating layer on a magnetic substrate with a magnetic thickness gauge.

       3.Microscopy

       The microscope method is also called metallographic method. It is to enlarge the etched fastener on a metallographic microscope with a micrometre eyepiece to measure the thickness of the coating on the section.

customized 3-56 machine screw countersunk phillips machine screw

       4.Timed flow method

       The timed flow method is to inject a solution capable of dissolving the plating layer on the local surface of the plating layer, and calculate the thickness of the plating layer according to the time required for the local plating layer to dissolve. There are plating method, anodic dissolution Coulomb method and so on.

      Inspection of coating adhesion strength

      There are many methods to evaluate the adhesion between the coating and the base metal, usually the following.

      1. Friction polishing test; 2. File method test; 3. Scratch method; 4. Bend test; 5 Thermal shock test; 6. Extrusion method.

       Fourth, the corrosion resistance of the coating

       The test methods for corrosion resistance of coatings are: atmospheric exposure test; neutral salt spray test; acetate salt spray test; copper accelerated acetate spray test; and corrosion paste corrosion test and solution drip corrosion test; immersion test and interleaving corrosion test and many more.

micro torx screw 0-80 6-lobe drive screws

       In short, the inspection of fastener surface treatment is a work with high technical requirements, which should be comprehensively and seriously treated to ensure the quality of the final product.